Can a battery run my AC?

Air conditioning is often the biggest load in a home, and the one people most want during a summer outage. Here is what decides whether a battery can run it, and for how long.

The short answer

Often yes, but it depends on two things: whether the battery can supply the brief surge when the compressor starts, and how much stored energy it has. In our example, a typical central air unit running about 3.5 kW for half of each hour uses about 1.75 kWh an hour, so one 13.5 kWh battery could run it alone for about 7 hours. Many homes need a soft starter, a second battery or a smaller cooling setup to make it work well.

Two hurdles: starting and running

An air conditioner’s compressor is an electric motor, and motors draw a burst of power for a moment when they start. That burst (the startup surge, or inrush current) can be several times higher than the running power, for a fraction of a second to a second or so. If the battery can’t supply it, the AC won’t start, or the battery’s protection will trip.

Once it is running, the AC draws a steadier amount of power. That running power, plus everything else on at the same time, has to stay under the battery’s continuous power rating, in kW. Finally, the total energy used over time, in kWh, decides how long the battery lasts.

  • Surge rating decides whether it starts.
  • Continuous power decides whether it keeps running alongside your other loads.
  • Usable storage decides how many hours you get.

You can estimate your AC’s running power from its nameplate, usually on the outdoor unit. Multiply the running amps (often labeled RLA, for the compressor) by the voltage, usually 240 volts for central air. For example, 15 amps × 240 volts = 3,600 watts, or about 3.6 kW. The fan adds a little more. An HVAC technician can confirm the figures.

A worked example: central air on one battery

Example: running central air during a summer outage

  • Example battery: 13.5 kWh usable, 5 kW continuous, with a higher short surge rating
  • Example central air unit: about 3.5 kW while running
  • On a hot day, the compressor runs about half of each hour
  • Energy per hour: 3.5 kW × 0.5 = about 1.75 kWh
  • Runtime on AC alone: 13.5 ÷ 1.75 = about 7.7 hours
  • Add essentials (fridge, lights, internet) at about 0.5 kWh an hour: 13.5 ÷ 2.25 = about 6 hours

About 6 to 7 hours of cooling from one battery, with no solar recharging

Example only. Real AC draw depends on unit size, efficiency, outdoor temperature and your thermostat setting. A hotter day or a larger unit shortens runtime. Solar recharging during the day can extend it.

Solar helps a great deal here, because hot, sunny days are when your panels make the most power. During a sunny afternoon, solar may cover much of the AC’s running power directly, leaving the battery for the evening. Our answer on how long a battery lasts in an outage shows how to add solar into the math.

Timing matters as much as size. If the outage starts at 6 p.m. on a hot evening, solar is fading just as the house is warmest, and the battery carries the full load into the night. If it starts at 9 a.m., solar can help all afternoon. Pre-cooling the house while the sun is out, then letting the temperature drift up a few degrees at night, can stretch a battery a long way.

Ways to make it work

  • A soft starter. A small device added to the AC that ramps the compressor up gently, cutting the startup surge. It is a common add-on when backing up central air with batteries. Ask an HVAC technician whether your unit is a good fit.
  • A second battery. Two batteries often double the continuous and surge power as well as the storage, which can be enough to start a larger unit.
  • An inverter-driven system. Many ductless mini-splits and some central heat pumps use variable-speed compressors that start gently and run at lower power much of the time, which is easier on a battery.
  • A window unit or one room. Cooling one room with a small unit uses far less power than cooling the whole house.
  • A higher thermostat setting. Setting the thermostat a few degrees warmer during an outage cuts how often the compressor runs.

A soft starter usually costs far less than a second battery, so it is often the first thing to try when a single battery can’t start your AC. It doesn’t add any storage, though, so it helps the AC start but doesn’t make the battery last longer.

Ask your installer for the battery’s surge rating and your AC’s locked rotor amps (LRA) or startup draw, from the unit’s nameplate. Comparing the two is the quickest way to know whether it will start.

Heat pumps and winter

If your AC is a heat pump, the same unit heats your home in winter. Heat pumps can run on batteries in the same way, but cold weather adds a twist. Many heat pumps have electric resistance backup heat (heat strips) that turn on in very cold weather or when the system falls behind. Those strips can draw a lot of power, often more than the heat pump itself, and can drain a battery quickly.

Winter outages also come with short days and weak sun, so solar refills the battery much less. If cold-weather outages are your main worry, ask your installer and HVAC technician whether the heat strips can be locked out during an outage, and size for winter. Our answer on whether a battery can power your whole house covers other big loads.

How to plan your setup

  1. Find your AC’s running power and startup draw on its nameplate, or ask an HVAC technician.
  2. Compare them with the battery’s continuous and surge ratings.
  3. Estimate how many hours of cooling you want, and multiply by the kWh per hour.
  4. Decide whether one battery with a soft starter, two batteries, or a smaller cooling setup fits your budget.
  5. Ask whether your solar keeps running in an outage so it can help power the AC during the day.

Our answer on how many batteries you need walks through sizing for all your loads, and battery sizing in Session 5 goes deeper. For more questions like this, visit the Q&A floor.

When backing up AC isn’t worth it

  • Your outages are short and mild, so you could ride them out with fans and a higher thermostat.
  • Running your AC would take several batteries that you would rarely need.
  • Your heat pump relies on heat strips in winter, which would drain a battery in hours.
  • A small window unit or a single mini-split would cool one room for a fraction of the cost.

Key takeaways

  • A battery must handle the AC’s startup surge, its running power and its energy use over time.
  • In our example, one 13.5 kWh battery runs typical central air for about 6 to 7 hours with essentials.
  • Soft starters, second batteries and inverter-driven systems make AC backup easier.
  • Heat pump backup heat strips can drain a battery quickly in winter outages.

Questions people also ask

Can a battery run a window air conditioner?

Usually, yes. Window units draw much less power than central air, often under 1.5 kW while running, and have smaller startup surges. One home battery can typically run a window unit for many hours along with essentials. Check the unit’s label for its wattage, and run the same runtime math to see how long your battery would last.

What is a soft starter for an air conditioner?

A soft starter is a small electronic device wired into your AC’s outdoor unit. It ramps the compressor up gradually instead of all at once, which can cut the startup surge a great deal. That makes it easier for a battery or a generator to start the AC. An HVAC technician can tell you whether it suits your unit.

Will running my AC on a battery damage it?

No, as long as the battery is sized and set up correctly. Running a large load simply uses stored energy faster. If the AC pulls more than the battery can supply, the battery’s protection system shuts it down to prevent damage. Heavy daily use does add cycles over the years, which counts toward normal wear.

Sources

Ready for real numbers on your roof?

No calls unless you ask. We never sell your details.