Production estimates in quotes

The production estimate is the number your savings are built on. If it’s too high, every savings figure on the quote is too high as well. Here is how to read it, what’s behind it, and how to check it yourself in about ten minutes.

The short answer

A production estimate is the installer’s forecast of how many kWh your system will make in its first year. Divide it by the system size in kW: across the US, most systems make about 1,100 to 1,600 kWh per kW a year, depending on location, roof direction, tilt and shade. You can check any estimate for free with PVWatts from the National Laboratory of the Rockies. If a quote is well above what PVWatts gives for your address, ask the installer to explain why.

Why this one number matters so much

A solar quote usually shows a bold savings figure: thousands of dollars over 25 years, a payback in some number of years, a percentage of your bill wiped out. Every one of those figures starts with the same input, the amount of electricity the system will make. Savings is just production multiplied by what each kWh is worth to you.

That means a production estimate that runs 20% high makes the savings run roughly 20% high too, and the payback look shorter than it will be. The price, the equipment and the warranties can all be fine, and the quote can still mislead you if this number is off. Fortunately, it’s also the easiest number to check.

A quick refresher on units. System size is in kilowatts (kW): how much power the panels can make at one moment in strong sun. Production is in kilowatt-hours (kWh): the energy made over time, the same unit on your electric bill. A quote should give production as a yearly kWh number, ideally with a month-by-month breakdown.

What goes into a production estimate

Installers use design software, often built on the same models as PVWatts, to forecast production. The software combines several inputs. Knowing them helps you see where an estimate can go wrong.

  • Location and weather. Years of solar and weather data for your area. Sunnier places make more power per kW.
  • Roof direction (azimuth). In the US, south-facing roofs usually make the most. East and west faces make less, and north faces much less.
  • Tilt. The angle of the panels. Most roof pitches work, but very flat or very steep roofs change output.
  • Shade. Trees, chimneys, vents and nearby buildings. Shade is the input most often underestimated, especially from trees that grow.
  • System losses. Wiring, inverter conversion, dust, snow, heat and small mismatches between panels. PVWatts uses a default loss setting of about 14% for these.
  • Equipment. Panel wattage and inverter type. Panel-level electronics can recover some output on shaded roofs.

Ask the installer for the design report behind the estimate. It should show the roof faces used, their direction and tilt, the shade analysis and the loss assumptions. A good installer will share it.

The quick test: kWh per kW

You don’t need special software for a first check. Just divide the first-year production estimate by the system size in kW. This gives the production ratio, or kWh per kW per year.

Across the US, a typical system makes about 1,100 to 1,600 kWh per kW per year depending on location, based on PVWatts. Cloudier northern areas sit near the bottom of that range, and sunny southwestern areas near the top. A roof that faces east or west, or has some shade, will usually come in lower than a clear south-facing roof in the same town.

Example: running the quick test

  • Quote A: 8 kW, first-year estimate 10,400 kWh, which is 1,300 kWh per kW
  • Quote B: 8 kW, first-year estimate 12,800 kWh, which is 1,600 kWh per kW
  • PVWatts for this example address (south roof, light shade): about 1,250 kWh per kW, or about 10,000 kWh

Quote A is close to PVWatts. Quote B is about 28% higher and needs an explanation.

Worked example. The PVWatts figure here is an assumption for illustration. Run your own address to get yours.

A number at the top of the national range isn’t wrong by itself, if you live somewhere very sunny with an ideal roof. The point is to compare the estimate with what’s realistic for your roof, not with the national average. If you don’t know where your area sits, PVWatts will tell you in a few minutes.

Check it yourself with PVWatts

PVWatts is a free online calculator from the National Laboratory of the Rockies (formerly NREL). It’s the closest thing to a neutral referee for production estimates. Here’s how to use it on a quote.

  1. Go to PVWatts and enter your street address.
  2. Enter the system size in kW DC from your quote.
  3. Choose the module type (standard is fine for most panels) and the array type (fixed roof mount).
  4. Enter the tilt in degrees and the azimuth (180 is due south, 90 east, 270 west). The quote or design report should list these. If not, estimate from your roof.
  5. Leave the system losses at the default unless you have heavy shade, in which case raise it.
  6. Read the annual kWh result and compare it with the quote.

If your roof has panels on two faces, run each face as a separate system and add the results. If PVWatts and the quote land within about 5% to 10% of each other, the estimate is in a reasonable zone. If the quote is much higher, ask the installer what they assumed differently. Sometimes there’s a good answer, like a better shade analysis from a site visit. Sometimes the estimate is simply optimistic.

PVWatts is an estimate too. It uses typical weather, not next year’s weather, and it doesn’t see your exact trees. Use it as a cross-check, not as a promise.

From production to savings: where the money estimate can drift

Even when the kWh figure is sound, the way a quote turns kWh into dollars can stretch the result. Look at four assumptions.

1. What each kWh is worth

If your utility gives full retail credit for power you send back (net metering), every kWh is worth roughly your full rate. Many utilities now pay less for exported power. California moved to net billing in April 2023, and average export credits there are around 4¢ per kWh, so power you use at home is worth far more than power you export. See does solar pay in California and the net metering session. Other states have their own rules, so check your state briefing.

2. Your electricity rate

The US average residential rate is about 17 to 18¢ per kWh in 2025 and 2026, according to the U.S. Energy Information Administration, but it ranges from about 11¢ to over 40¢ in Hawaii. The quote should use your actual rate from your bill, including delivery charges that solar offsets, but not fixed monthly fees that solar can’t reduce.

3. Yearly rate increases

Many savings tables assume your rate rises a few percent every year for 25 years. That might happen, or it might not. Ask to see the savings with no rate increase too, so you know how much of the promised savings depends on that guess.

4. Panel aging

Panels often lose about 0.5% of output a year. A careful quote builds this in. One that shows flat production for 25 years overstates lifetime output.

Example: what an inflated estimate does to payback

  • 8 kW system at $24,000, valued at 16¢ per kWh with full retail net metering
  • Claimed: 12,800 kWh a year, saving about $2,050, payback about 11.7 years
  • Realistic for this roof: 10,000 kWh a year, saving about $1,600, payback about 15 years

The optimistic estimate makes payback look more than 3 years shorter than it really is

Worked example. Simple payback is the price divided by first-year savings, ignoring rate changes, panel aging and financing. Lower export credits would stretch both figures further.

Lifetime production and what it tells you

Some quotes also show total production over 25 years. That figure is useful because it lets you work out what you’re really paying per kWh over the system’s life, and compare it with your utility rate.

Example: the standard example home over 25 years

  • First-year production: about 10,400 kWh
  • Output falls about 0.5% a year
  • Total over 25 years: about 245,000 kWh (not 260,000, which ignores aging)
  • System price: $24,000

About 9.8¢ per kWh over 25 years, before any repairs or inverter replacement

Worked example. It leaves out financing costs, maintenance and a possible inverter replacement, which would raise the cost per kWh. It also assumes the system keeps running for the full 25 years.

If your utility charges 16¢ per kWh and solar costs you about 10¢ over its life, that’s a real saving, as long as you can use or get good credit for most of the power. If your export credit is far below 10¢, the power you export doesn’t pay its way. That’s the honest heart of the question, covered in when solar doesn’t pay.

Reading the monthly breakdown and the offset percentage

A good quote doesn’t stop at one yearly number. It shows production month by month next to your usage month by month. That chart tells you two things the yearly figure hides.

First, solar is seasonal. In most of the US, panels make far more in late spring and summer than in December. If your utility uses net metering with credits that roll over from month to month, summer surplus can cover winter shortfall. If credits expire monthly or are paid at a low export rate, the summer surplus is worth much less, and the monthly chart shows you how much of your power falls into that gap.

Second, the chart shows the share of your yearly use the system covers (the offset percentage). It’s simply yearly production divided by yearly use.

Example: offset for the standard example home

  • Home uses 1,100 kWh a month, or 13,200 kWh a year
  • 8 kW system makes about 10,400 kWh in year one
  • 10,400 divided by 13,200

Offset of about 79%

Worked example. A quote showing 100% or more offset isn’t automatically better. Under weak export credits, the last slice of production is often worth the least.

If a quote pushes you toward a bigger system to reach 100% or more, ask what the extra panels are worth under your utility’s export rules. For more on this, see what is an offset percentage. And because a bigger system lowers the price per watt but not always the cost per useful kWh, it’s worth reading price per watt explained alongside this page.

Questions to send the installer about any estimate

  • Which roof faces did you use, and at what tilt and direction?
  • How did you measure shade, and when?
  • What loss percentage did you assume?
  • What rate, export credit and yearly rate increase did you use to turn kWh into savings?
  • Can you show the savings with no rate increase at all?

Production guarantees and what happens if you fall short

Some installers and financing companies back their estimate with a production guarantee: a written promise that the system will make at least a certain number of kWh, with a payment to you if it doesn’t. These can be useful, but read the terms closely.

  • What share of the estimate is guaranteed? Often it’s less than 100%.
  • Is it measured each year or over several years combined?
  • Does bad weather, shade from new tree growth or a utility outage count as an exception?
  • How is a shortfall paid: cash, a bill credit, or a lower payment?
  • Does the guarantee transfer if you sell the house?

A guarantee is not a substitute for a realistic estimate. If an installer guarantees 90% of an inflated number, you may still end up below what you were sold. Read more in what is a production guarantee. Once your system is running, compare your monitoring app with the estimate month by month. A shortfall in the first few months may just be weather, but a steady gap is worth raising with your installer early, while the workmanship warranty is fresh.

To see how production fits with price and warranties when you line up several quotes, read comparing three solar quotes, and return to the How to read an installer quote session for the whole picture.

When the production math doesn’t add up

  • Your roof faces mostly north or sits in heavy shade, and PVWatts gives a figure near or below the bottom of the national range.
  • Most of your production would be exported at a low credit, such as the roughly 4¢ per kWh average under California’s net billing.
  • The quote only pays back if you accept a production estimate far above PVWatts for your address.
  • Trees you don’t control, such as a neighbor’s, are likely to grow and add shade over the years.
  • Your lifetime cost per kWh comes out close to, or above, what your utility charges.

In those cases, a smaller system, a different roof face or no solar at all may be the honest answer.

Key takeaways

  • Savings are production times what each kWh is worth. An inflated kWh estimate inflates every savings figure.
  • Divide first-year kWh by system kW. Most US systems make about 1,100 to 1,600 kWh per kW a year, depending on location.
  • Check the estimate for your address with PVWatts. If the quote is much higher, ask why.
  • Watch the dollar assumptions: export credit, your real rate, yearly rate increases and panel aging.
  • A production guarantee helps, but only if the number it guarantees was realistic to begin with.

Questions people also ask

Why does my first year come in below the estimate?

Weather varies from year to year, and estimates use typical weather, so a cloudy or smoky year can fall short while a sunny one runs ahead. Snow, dust and a late switch-on date can also trim the first year. Compare a full 12 months against the estimate. If you’re still well short after a year, ask your installer to check for shade, faults or design problems.

Should I trust an estimate that uses satellite shade data?

Satellite tools are good for a first quote, but they can miss newly grown trees or small obstructions like vent pipes. Before you sign, ask whether someone will measure shade on site. If the site visit changes the estimate, the installer should update the quote so the savings figures you are relying on match the final design.

Is a higher production estimate a sign of a better system?

Only if the difference comes from the design, such as more panels on a better roof face or panel-level electronics on a shaded roof. If two similar systems on the same roof show very different estimates, the higher one is more likely using rosier assumptions. Run both through PVWatts and ask each installer to explain the gap.

Does the estimate include power I will export?

Yes. Production is everything the panels make, whether you use it at home or send it to the grid. What changes is the value. Under full retail net metering both are worth about the same, but many utilities pay less for exports. Ask the installer to show how much of the estimate they expect you to use directly.

Sources

Ready for real numbers on your roof?

No calls unless you ask. We never sell your details.